Still deciding? Get samples of $ !
Request Sample
|
| Customization: | Available |
|---|---|
| Type: | Signal Type Arrester |
| Structure: | Monobloc Design |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Protection Introdction
Technical Data
|
Type |
BS BNC 5V |
|
Art.-No. |
BS BNC 5V(A)630019/BS BNC 5V(B)630020 |
|
Nominal voltage [UN] |
5V |
|
Rated voltage (max. continuous d.c. voltage) [Uc] |
8V |
|
Lightning impulse current (10/350) [Iimp] |
0.5kA |
|
Nominal discharge current (8/20) (line-shield) [In] |
2.5kA |
|
Nominal discharge current (8/20) (shield-PG) [In] |
5kA |
|
Max. discharge current (8/20) (line-shield) [Imax] |
5kA |
|
Max. discharge current (8/20) (shield-PG) [Imax] |
10kA |
|
Voltage protection level 1kV/us (line-shield) [Up] |
≤ 15V |
|
Voltage protection level 1kV/us (shield-PG) [Up] |
≤ 600V |
|
Bandwidth (line-line) [fG] |
300MHz |
|
Characteristic impedance[Z] |
75 Ω |
|
Response time (line-line) [tA] |
≤ 1ns |
|
Response time (line-PG) [tA] |
≤ 100ns |
|
Max. data transmission rates [Vs] |
16Mbits/s |
|
Operating temperature range [Tu] |
-40°C...+80°C |
|
Connection input/output |
BNC Male to BNC Female |
|
Mounting on |
35mm DIN rail, EN 60715(Type A) |
|
Enclosure material |
Aluminum |
|
Earthing via |
BS BNC 5V(A): Earthing screw |
|
Earthing via |
BS BNC 5V(B): outgoing cable1.5mm2 x 300mm |
|
Shield earthing |
Indirectly via integrated spsrk gap |
|
Compliance |
IEC 61643-21; EN 61643-21; GB 18802.21 |
|
Certification |
CE, RoHS |
Hightlight Features
1. Coaxial Cable Surge Protection.
2. For Analog CCTV Cameras (NTSC / PAL).
3. Supports HD-TVI, AHD, and HDCVI HD Cameras.
4. BNC Male to BNC Female(BNC Female to BNC Female,Optional.)
5. Protects Equipment from Voltage Surges from Nearby Lightning.
6. Recommended 2 Units Installed per Camera - One mounted at DVR / One at CCTV Camera.
7. Optional with 35mm DIN rail installation.
Summary
BS BNC 5V is for protecting coaxial cable transmission devices from interruption caused by surge voltage, surge protective device uses BNC connection, provide reliable protection for coaxial cable transmission devices or video signal transmission devices from surge, operating over voltage and electrostatic discharging. Designed according to GB 18802.21 / IEC 61643-21.