Still deciding? Get samples of $ !
Request Sample
|
| Customization: | Available |
|---|---|
| Type: | Power Source Arrester |
| Structure: | Pluggable Design |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
|
Type |
BT PCM60 TT2+1 275 RM |
BT PCM60 TT2+1 320 RM |
|
According to IEC 61643-11/EN 61643-11 |
Class II / Type 2 |
Class II / Type 2 |
|
Art.-No. |
810993 |
810994 |
|
Nominal a.c. voltage [UN] |
230V/400V |
230V/400V |
|
Rated voltage (max. continuous a.c. voltage) [Uc][L-N / N-PE] |
275V/255V |
320V/255V |
|
TOV voltage[UT][L-N / N-PE] |
335V/5sec, 1200V/200ms |
335V/5sec, 1200V/200ms |
|
Frequency[Hz] |
50/60 Hz |
50/60 Hz |
|
Nominal discharge current (8/20μs)[In][L-N / N-PE] |
30kA/40kA |
30kA/40kA |
|
Max. discharge current (8/20μs) [Imax][L-N / N-PE] |
60kA/65kA |
60kA/65kA |
|
Voltage protection level at In [Up][L-N / N-PE] |
≤1.5kV/≤1.5kV |
≤1.6kV/≤1.5kV |
|
Voltage protection level at 5kA [Up][L-N ] |
≤1.2kV |
≤1.3kV |
|
Response time [tA][L-N / N-PE] |
≤ 25ns/≤ 100ns |
|
|
Follow current extinguishing capability at Uc[If] (N-PE) |
100Arms |
|
|
Max. back up fuse [F] |
125A gL/gG |
|
|
Operating temperature range [Tu] |
-40°C...+80°C |
|
|
Cross-sectional area |
1.5mm2~ 25mm2 solid / 35mm2 flexible |
|
|
Mounting on |
35mm DIN rail,EN 60715 |
|
|
Operating state / Failure indication |
Green:ok / Red: faulty |
|
|
Dimension |
3 mods (54mm wide) |
|
|
Enclosure material |
L-N(Purple) +N-PE(Light gray)module & light gray (base) thermoplastic, UL94-V0 |
|
|
Test standards |
IEC 61643-11:2011 ; EN 61643-11:2012; GB/T 18802.11-2020 |
|
|
Certification |
CE; RoHS |
|
|
Number of remote terminals |
1(or Optional) |
|
|
Type of remote signaling contact |
Switching contact |
|
|
Switching capacity(UN/IN) |
AC:250V/0.5A; DC:250V/0.1A;150V/0.2A;75V/0.5A |
|
|
Cross-sectional area for remote signaling contact |
Max. 1.5mm2 solid/flexible |
|

Hightlight Features
1. Pluggable module, easy for installation and maintenance.
2. High discharge capacity, quick response.
3. Double thermal disconnector devices, providing more reliable protection.
4. Green window will change when fault and also provide remote alarm control at the same time.
5. Mode of protection:L1,L2,N, PE.
6. Suitable for TT/ TN installations.
7. Crafted from selected flame-retardant enclosure and Utilizing advanced European technology to ensure complete and reliable safeguarding of electrical equipment.
Summary
Designed for installation in LPZ 0B-1 or higher zones, this surge protection device safeguards low-voltage equipment from power surges and remote terminal is optional.Application:Pluggable SPD Class II for TT/TN("2+1" circuit) power supply systems. Compliance Standards:IEC 61643-11:2011;EN 61643-11:2012;GB/T 18802.11-2020.
Application Environment
Temperature:-40°C...+80°C.
Relative humidity:≤ 95%(25°C)
Main Products
Application Scenarios
Our Services
Company Profile
Our Advantages
Our Equipments
Protduction Process
Our Teams
Certificates
FAQ
Packaging & Shipping