Still deciding? Get samples of $ !
Order Sample
|
| Customization: | Available |
|---|---|
| Type: | Isolating Spark Gap |
| Structure: | Monobloc Design |
| Shipping Cost: | Contact the supplier about freight and estimated delivery time. |
|---|
| Payment Methods: |
|
|---|---|
| Support payments in USD |
| Secure payments: | Every payment you make on Made-in-China.com is protected by the platform. |
|---|
| Refund policy: | Claim a refund if your order doesn't ship, is missing, or arrives with product issues. |
|---|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency

Technical Data
|
Type |
ISG 10 S |
ISG 10 |
|
Art.-No. |
690001 |
690015 |
|
According to EN 62561-3 / IEC 62561-3 |
Yes |
|
|
Application |
Earthing Devices for Lightning Equipotential Bonding |
|
|
Rated DC withstand voltage[Uc] |
350V |
350V |
| Rated impulse spark over voltage[Urimp]
|
1000V |
1000V |
|
Lighting impulse current (10/350µs) |
100kA |
100kA |
|
Nominal discharge current (8/20µs) [In] |
100kA |
100kA |
|
Max. discharge current (8/20µs) [Imax] |
200kA |
100kA |
| 100% lightning impulse sparkover voltage[Uas] | ≤ 1.5kV | ≤ 1.5kV |
|
Power frequency sparkover voltage(50Hz)[Uaw] |
≤ 400V |
≤ 400V |
| Length of enclosure | 123mm | 148mm |
| Connection | Rd 10 mm | Rd 15 mm |
|
Ex certification, according to EN 60079-0 and EN 60079-1:Gas |
Ex db IIC T6 Gb |
|
|
Ex certification, according to EN 60079-0 and EN 60079-31: Dust |
Ex tb IIIC T80 °C Db IP 66/67 |
|
| Capacitance at 1 MHz[C] |
≤ 10pF |
|
| Insulation resistance at 100V [R] | >1GΩ | |
|
Diameter of enclosure |
40mm |
|
|
Enclosure material |
Orange thermoplastic, UL 94-V0 |
|
|
Connection via |
M8 theraded screws |
|
| Operating temperature range [Tu] | -40°C...+80°C | |
|
Connection material |
Stainless steel |
|
|
Protection level |
IP67 |
|
|
Certification |
CE (LVD, EMC); RoHS |
|
| Compliance |
EN 62561-3;IEC 62561-3;GB/T 33588.3 |
|

1.Earthing Device according to lEC/EN 62305 in hazardous areas.
2.10mm stainless steel material connection terminal.
3.For mounting in-door or out-door, in damp rooms as well as for underground installation.
4.Extremely loadable unit.
5.Ex marking/IP: Ex db llC T6 Gb, Ex tb lllC T80'C Db IP 66/67.
ISG 10 S Installation
ISG 10 Installation
Summary
1. Used for indirect connnection / earthing of function insulation components during lightning strikes.
2. According to IEC 62305,earting for equipotential connections for lightning strikes in hazardous areas.
3. For lightning equipotential bonding, especially for connection of separated earthing systems.
Main Products
Application Scenarios
Our Services
Company Profile
Our Advantages
Our Equipments
Protection Process
Our Teams
Certificates
FAQ
Packaging & Shipping