Type |
BT P BCM 25 RM/3+N |
|
Art.-No. |
800915 |
|
According to IEC 61643-11/EN 61643-11 |
Class I+Class II / Type 1 +Type 2 |
|
Nominal a.c. voltage [UN] |
230V/400V(50/60Hz) |
|
Rated voltage (max. continuous voltage) [Uc](L-N/N-PE) |
255V(50/60Hz) / 255V(50/60Hz) |
| Total Lightning impulse current(10/350μs)[Iimp] | 100kA(L+N-PE) |
|
Lightning impulse current (10/350μs) [Iimp] (L-N/N-PE) |
25kA/50kA |
|
Nominal discharge current (8/20μs) [In](L-N/N-PE) |
50kA/50kA |
|
Max. discharge current (8/20μs) [Imax](L-N/N-PE) |
75kA/75kA |
|
Voltage protection level at In [Up](L-N/N-PE) |
≤ 1.5kV/≤ 1.5kV |
|
TOV voltage[UT](L-N/N-PE) |
335V/5sec |
|
TOV 120 min(safe fail)[UT][L-N] |
440V |
| TOV voltage[UT](N-PE) | 1200V/200ms |
|
Follow current extinguishing capability at Uc |
32A fuse will not be triggered at 2kArms |
|
Response time [tA] |
≤ 100ns |
|
Max. back up fuse (L) [F] |
200A gL/gG |
|
Max. back up fuse (L-L') [F] |
125A gL/gG |
|
Operating temperature range [Tu] |
-40°C...+80°C |
| Degree of protection |
IP 20 |
|
Max. cross-sectional area |
10mm2-35mm2 solid / 50mm2 flexible |
|
Mounting on |
35mm DIN rail, EN 60715 |
|
Enclosure material |
Purple (or Gray/Red module, Optional) & light grey (base) thermoplastic, UL94-V0 |
|
Number of remote terminals |
1(or Optional) |
|
Dimension |
4 mods(72mm wide) |
|
Test standards |
IEC 61643-11:2011 ; EN 61643-11:2012; GB/T 18802.11-2020 |
|
Certification |
CE(LVD,EMC), RoHS |
|
Type of remote signalling contact |
Switching contact |
|
Switching capacity(UN/IN) |
AC:250V/0.5A; DC:250V/0.1A;150V/0.2A;750V/0.5A |
|
Cross-sectional area for remote signalling contact |
Max. 1.5mm2 solid / flexible |




1. Surge protection device suitable for TT/TN-S("3+1" circuit) installation.
2. Use for Three-Phase Five-Wire system.
2. Adopt hermetical High Energy Gas Discharge Tube(GDT) technology, high follow current extinguishing capability.
3. Extremely low voltage protection level.
4. Double thermal disconnection device , provide more reliable protection.
5. Multifunctional connection for conductors and busbars.
6. Green window will change to red when fault occurs, also provide remote alarm terminal at the same time.
7. Mode of protection:L-N; N-PE.
7. Suitable for use in three phase: 220V/380V(50/60 Hz), 240V/415V(50Hz), 230V/400V(50/60 Hz) AC systems.
8. Crafted from selected flame-retardant enclosure and Utilizing advanced European technology to ensure complete and reliable safeguarding of electrical equipment.
Summary
BT P BCM 25 RM/3+N(800915) is for installation at LPZ 0A-1 or higher, protecting low voltage equipment from surge damage remote terminal is optional. Application:Applied in pluggable SPD Class I + Class II (Class B + Class C) for 3 phase TT/TN-S ("3+1" circuit) power supply system. Compliance Standards:IEC 61643-11:2011;EN 61643-11:2012;GB/T 18802.11-2020.