Protection Introduction

|
Type |
BT 5L BM 415 RM |
|
Art.-No. |
820303 |
|
According to EN 61643-11, IEC 61643-11 |
Type 1 + Type 2 + Type 3 / Class I +Class II + Class III |
|
Nominal a.c. voltage [UN] (L-N) |
240V |
|
Rated voltage (max. continuous voltage) [Uc](L-N) |
280V |
|
Transient overvoltage TOV[UT] |
350V |
|
Short-circuit withstand capability |
25kA/50Hz |
|
Operating voltage |
346-484V |
|
Frequency range[F] |
47-63Hz |
|
Leakage current (to the ground) |
<250μA |
|
Indicator circuit current |
<10mA |
|
Lightning impulse current (10/350μs[Iimp] |
6.25kA |
|
Total Lightning impulse current (10/350μs) [Iimp] |
25kA |
|
Nominal discharge current (8/20μs) [In] |
20kA(per mode) |
|
Voltage protection level at Iimp [Up] |
≤ 1.2kV |
|
Max. discharge current (8/20μs) [Imax] |
40kA(per mode) |
|
Voltage protection 1.2/50 6kV@3kA[Up] |
≤ 0.6kV |
|
Max. back up fuse [F] |
125A gL/gG |
|
perating temperature range [Tu] |
-40°C...+80°C |
|
Enclosure material |
Black metal(Iron) housing |
|
Connection type |
Screw terminals |
|
Wiring conductor cross section |
10mm2 ~ 16mm2 |
|
Compliance |
IEC 61643-11:2011 ; EN 61643-11:2012; GB /T18802.11-2020 |
|
Degree of protection |
IP 20 |
|
Certification |
CE (LVD, EMC); RoHS |
BT 5L BM 415 RM(3 Phase Surge Protection Device Box) Application Scenarios
T1+T2+T3 3 Phase AC Full Protection Main Distribution Boards.
Hightlight Features
1. All wires (phase line to neutral line, phase line to ground, neutral line to ground full protection mode) voltageprotection level is very low.
2. Full protection design, able to handle part of lightning current, protection equipment can continue normal operation.Repeated protection of innovative multiple themal fuse technology in a lightning-intensive environmentpart of the protection circuit that causes an abnormality or malfunction can be safely disconnected fromthe power supply system. (does not affect the protection performance of the normal part)
3. Visual protection status indication, with pre-failure indication and failure indication function.
4. With remote alerting function, remote warning signal can be connected to the remote monitoring management system platform buzzer or LED.
5. Visual warning indication of neutral/ground line fault due to faulty wiring.
6. Mode of protection:L1,L2,L3,N, G.
7. Solid housing, base can be used as ultra-low inductance grounding metal panel.
8. Suitable for use in three phase: 220V/380V(50/60 Hz), 240V/415V(50/60 Hz), 230V/400V(50/60 Hz) AC systems compatible.
Dimension
Installation
Summary
BT 5L BM 415 RM(820303) power surge protector is installed in the LPZ0B -1, interface and is mainly used in the main distribution system toprotect the connected electronic devices from the transient over voltage on the power supply. For example.computer,communication or control equipment. Applied in three phase type 1 +type 2 +type 3 for various power supply system.